What a sugar COA is — and what it is not
A Certificate of Analysis (COA) is a laboratory’s report of the measured values for a defined sample of sugar: which lot it represents, what was tested, by which method, and with what result. It is the document that shows a shipment meets the agreed specification. Three neighbouring documents are often confused with it:
- Specification sheet — the limits a product is sold against, such as max. 45 IU. It describes the product, not a lot.
- Certificate of weight, quality and packing — issued at loading by the seller’s appointed supervisor or an inspection company. ICE White Sugar requires one covering polarisation, moisture and colour, and the Refined Sugar Association (RSA) rules list it among the documents presented for payment.
- Certificates of origin, halal status, free sale and similar — these attest origin, compliance or certification, not lot quality. See sugar export documentation.
A producer’s COA and an independent inspection certificate often travel together: the first records the producer’s own testing of the lot, the second what an independent party sampled and found at loading. Thai customs may also ask for a certificate of analysis or a specification when the type and quality of exported goods are hard to identify, according to Thailand’s National Trade Repository.
What a complete COA contains
| Section | What to look for | Why it matters |
|---|---|---|
| Issuer | Laboratory or company name, address, signatory and contact details | You must be able to verify who produced the result |
| Product and grade | Description and grade exactly as in the contract (for example refined sugar, max. 45 IU) | Links the COA to the contract item |
| Lot identification | Lot or batch number, production date or crop year, quantity represented, container numbers or bag marks | Ties the result to the goods on the packing list and bill of lading |
| Sampling | Who drew the sample, where, when and how (for example per 1,000 t lot) | A result is only as good as the sample behind it |
| Results | Every contract parameter, each with a numeric result and unit | A missing parameter cannot be checked |
| Methods | The ICUMSA (or other recognised) method for each parameter | Different methods can give different numbers |
| Limits and conformity | The contract limit beside each result and a clear conformity statement | Makes the comparison explicit |
| Dates and signature | Sampling, analysis and report dates; signature | Dates must fit between production and shipment |
The methods behind the numbers
Sugar analysis methods are set by ICUMSA, the International Commission for Uniform Methods of Sugar Analysis — a methods body, not a grade or a certificate. The RSA rules require contract samples to be analysed by a recognised analytical chemist using ICUMSA or another internationally recognised method and, unless the contract says otherwise, solution colour by ICUMSA GS9/1/2/3-8 (2011). Since its 2024 Methods Book ICUMSA uses shorter method numbers (GS2/3-9 is now GS2-9), so either style may appear on a COA.
| Parameter | ICUMSA method | Scope and notes |
|---|---|---|
| Colour | GS2-10 | Official; white sugars up to 50 IU, no pH adjustment; repeatability ≤ 3 IU, reproducibility ≤ 7 IU |
| Colour | GS2-9 (old GS2/3-9) | Accepted; crystalline sugars of 20–600 IU, pH 7.0 with TEA/HCl buffer |
| Colour | GS1-7 (old GS1/3-7) | Official; raw, brown and coloured sugars of 250–16,000 IU, pH 7.0 |
| Colour | GS9-8 | Official reference method (MOPS buffer), 10–16,000 IU; recommended in disputes |
| Polarisation | GS2-1 (white) / GS1-1 (raw) | Polarimetry; reproducibility ≤ 0.094 °Z (GS2-1) and ≤ 0.25 °Z (GS1-1) |
| Moisture | GS2-15 | Loss on drying at 105 °C for 3 hours |
| Conductivity ash | GS2-17 (white) / GS1-13 (raw) | Measures soluble salts; not directly comparable with incineration ash |
| Reducing sugars | GS2-5 / GS2-6 | Purified sugars / white and plantation white sugar |
| Sulphite (SO₂) | GS2-33 | White and plantation white sugar |
| Granulation | GS2-37 | Sieving; reports mean aperture (MA) and coefficient of variation (CV) |
| Microbiology | GS2-41, GS2-47, GS2-53 and others | Mesophilic aerobic bacteria, yeasts and moulds, osmotolerant yeasts in white sugar |
One consistency check follows directly: a colour method must suit the range it reports. A result of 45 IU belongs to GS2-10, GS2-9 or GS9-8 — not to GS1-7, whose scope starts at 250 IU.
How to check a COA against your contract
- Match the identifiers. Lot numbers, quantity, container numbers and bag marks should agree with the packing list, bill of lading and bag marking.
- Check the sample. Under RSA rules, unless the contract says otherwise, samples are drawn at random from at least 1 % of each 1,000 t (or part) from each supplier, and composite samples are sealed airtight for analysis. A COA that cannot say where its sample came from proves little.
- Compare each result with the contract limit, not with a ‘typical’ value or a different standard. If the contract says max. 45 IU by GS9-8, a result by another method is not the agreed test.
- Check units and bases. Pol in °Z; moisture as loss on drying; wet or dry basis for raw sugar pol; colour at the ICUMSA pH of 7.0 — a 2010 ISSCT paper notes colour measured at pH 8.5 is sometimes twice the pH 7 value.
- Allow for method precision. Two competent laboratories will not report identical numbers: GS2-10 states a reproducibility of ≤ 7 IU for white sugar colour, and ICE No. 11 averages pol results that differ by less than 0.15° but sends larger differences to an umpire.
- Check the dates. Sampling and analysis should fall between production and loading, and the report should cover the goods actually shipped.
Points to confirm on a COA
- A lot number, sampling details and a quantity that match the shipment
- A method reference for every result, and a method suited to the value reported — for example a white-sugar colour method for a 45 IU result
- Results specific to the lot, not repeated across shipments
- Every parameter named in the contract
- Dates that fit — analysis after production and before or at loading
- Contact details for the issuing laboratory or inspection company
If any point is unclear, ask the supplier — each one should have a straightforward answer. ANUTIDA states the specification with each quotation and documents each lot with a COA — see our quality approach.
When results disagree
Agree the dispute route before shipping. Under the RSA rules (August 2026 edition), the buyer must notify a quality claim within 7 days of completion of discharge; for containers, discharge counts as complete when the seal is broken, on delivery to the final receiver, or 40 days after discharge onto the quay, whichever is sooner. Claim samples are drawn in triplicate by an internationally recognised superintendence company from at least 5 % of the quantity involved and sealed airtight: one goes to the seller, one stays with the buyer and one is kept for arbitration.
For raw sugar on ICE No. 11 terms, the shipper’s weights and tests at the loading port, supervised by an independent company, are the basis of final settlement. Whatever rules apply, name your inspection company in your quotation request so that its role is written into the contract.
Frequently asked questions
Who issues a sugar COA?
The producing mill or refinery’s laboratory, an independent inspection company, or both. ICE White Sugar requires a certificate of weight, packing and quality issued by the seller’s supervisor, and RSA rules let buyer and seller each appoint an internationally recognised superintendence company.
Is the producer’s COA enough, or do I need independent inspection?
That is a contract decision. Inspection companies such as Intertek and Bureau Veritas offer sugar sampling, weighing supervision and testing to ICUMSA methods. If you want one, name it in your enquiry and agree who pays.
Does a COA prove halal status or food-safety certification?
No. A COA reports quality parameters for a lot. In Thailand halal certificates are issued through the Central Islamic Council of Thailand (CICOT), and Thai FDA issues export certificates such as a Certificate of Free Sale on request. Confirm what your market requires before contracting.
Why do my laboratory’s results differ from the COA?
Some difference is normal: methods have stated reproducibility limits, and sugar can change in transit or storage — raw sugar colour can rise during long storage. Check that both laboratories used the same method, pH and basis, then follow the contract’s claim procedure if the gap is larger.
Which parameters should a white sugar COA report?
At minimum those in your contract. ICE White Sugar certificates cover polarisation, moisture and colour; contracts can add ash, invert sugar, SO₂, granulation and microbiology. See how to read a sugar specification.
Sources & references
- Industry bodyRules Relating to Contracts (edition effective 26 August 2026) — The Refined Sugar Association
- RegulatorICE Futures White Sugar Futures Contract — Contract Rules (Section IIII) — ICE Futures Europe
- RegulatorSugar No. 11 Rules (Chapter 11 rulebook) — ICE Futures U.S.
- GovernmentProcedures and Documentary Requirements (Export) — Thailand National Trade Repository
- Standards bodyAims — about ICUMSA — ICUMSA (International Commission for Uniform Methods of Sugar Analysis)
- Standards bodyNew numbering system for ICUMSA methods — ICUMSA (International Commission for Uniform Methods of Sugar Analysis)
- Standards bodyICUMSA Method GS2-10 (2024) — abstract — ICUMSA (International Commission for Uniform Methods of Sugar Analysis)
- Standards bodyICUMSA Method GS2-9 (2024) — abstract — ICUMSA (International Commission for Uniform Methods of Sugar Analysis)
- Standards bodyICUMSA Method GS1-7 (2024) — abstract — ICUMSA (International Commission for Uniform Methods of Sugar Analysis)
- Standards bodyICUMSA Method GS9-8 (2026) — abstract — ICUMSA (International Commission for Uniform Methods of Sugar Analysis)
- Standards bodyICUMSA Method GS2-1 (2022) — abstract — ICUMSA (International Commission for Uniform Methods of Sugar Analysis)
- Standards bodyICUMSA Method GS1-1 (2022) — abstract — ICUMSA (International Commission for Uniform Methods of Sugar Analysis)
- Standards bodyICUMSA Method GS2-15 (2007) — abstract — ICUMSA (International Commission for Uniform Methods of Sugar Analysis)
- Standards bodyICUMSA Method GS2-17 (2011) — abstract — ICUMSA (International Commission for Uniform Methods of Sugar Analysis)
- Standards bodyICUMSA Method GS2-37 (2007) — abstract — ICUMSA (International Commission for Uniform Methods of Sugar Analysis)
- Standards bodyMethods archive — ICUMSA (International Commission for Uniform Methods of Sugar Analysis)
- ResearchKochergin, V. (2010) Studies of long-term storage of high quality raw sugar, Proc. ISSCT Vol. 27 — International Society of Sugar Cane Technologists
- ReferenceSugar inspection and testing services — Intertek Agri Services
- ReferenceSugar inspection and quality control services — Bureau Veritas Commodities
- ReferenceHalal certification portal — The Central Islamic Council of Thailand (CICOT)
- GovernmentFood export — certificates for export — Thai Food and Drug Administration, Food Division